首页    超电模组    64V40WH-变电站DC-DC变换装置
电容池

64V40WH-变电站DC-DC变换装置

img1

 

超级电容模组  V1.00

超级电容产品事业部

Supercapacitor Product Division

 

 

 

    

Product specification

 

 

 

 

Customer  客户名称:                                      

 

Product  产品名称:    模组型锂离子超级电          

 

Description    /型号:  PLM64V40WHT

 

 

Date         期:   2024 04  01               

 

Version No.      号:            V1.00                          

 

 

Prepared 制作

Checked 审核

approval 批准

 

 

 

Customer Approve 客户承认

 

 

 

img3

 

超级电容模组  V1.00

1.适用范 Introduction

本规格书规定SLM64V40WHTDB 锂离子电容器模组性能、测试方法  进行技术规范 化,作为技术确认依据。

This Specification describes the SLM64V40WHTDB properties, testing methods and notice of LIC by ShangHai YongMing Electronic Co.,Ltd

2.标准测试条 Standard test condition

一般情况下,在标准大气压下,温度 15~35,湿85%RH,大气压 86Kpa~106Kpa 条件下 进行测试;测试前样品应该在常温下放 12H 以上。

如对结果有疑问时,应按照温度 25±2,湿度60~70%RH ,标准大气 86Kpa~106Kpa 条件测量。

Generally  the  features  of  EDLC  should  be  tested  under  humidity   85%RH  and atmospheric pressure  86Kpa~106Kpa after place the samples at a room temperature 15~35 for 12h .

If any doubt of the result, please test the samples under temperature 25±2 , humidity 60~70%RH atmospheric pressure 86Kpa~106Kpa.

3.依据规 According to the specification

IEC 62813:2015《电气和电子设备用锂离子电容器电气特性试验方法》

IEC 62813:2015Lithium ion capacitors for use in electric and electronic equipment. Test methods for electrical characteristics》;

IEC 62931-1《电子设备用固定电双层电容器。 1 部分通用规范》

IEC 62931-1Fixed electric double-layer capacitors for use in electronic equipment  Part 1:Generic specification》;

IEC 62931-2《电子设备用固定电双层电容器。 2 部分通用规范》

IEC 62931-2Fixed electric double-layer capacitors for use in electronic equipment  Part 2:Generic specification》;

 

img4

 

超级电容模组  V1.00

 

项目 Test project

                      Specifications

 explain

 

 

 

 

 

 

 

 

 

 

 

电气特 Electrical characteristics

额定电压 voltage

64V

 

最大工作电 Max operating voltage

67V

 

最小工作电 Min operating voltage

42V

 

持续充电电 Rated current

10A

 

持续放电电 Rated current

10A

 

最大峰值放电电流  Max Peak current

40A

时间 time 1s,24h 不重复 Don't repeat

 

储存能 Storage Energy

 

40Wh

@25,   1.1A 恒流充电至 60.8V,恒压 15min 40W 恒功率放电至 42V

 

额定容 rated Capacitance

 

150F

@25,   1.1A 恒流充电至 60.8V,恒压 15min 1.1A 恒流放电至 43.2V

容量公差

Capacitance deviation

0%~30%

 

交流内阻 AC-ESR

140mΩ

@25

均衡管 Balanced management

 

 

安全监测

Safety monitoring

过压保护

overvoltage   protection

 3.1

欠压保护

downvoltage   protection

 3.1

过温保护

Over temperature protection

 3.1

 

环境特性

Environmental features

工作温 Working temperature

-20~70

 

储存温 Storage temperature

-40~70

 

湿度特性

Humidity characteristics

70%

无凝露

防护等  Protection grade

IP45

金属壳封装

循环寿命 Cycle life

10 万次

@25,  1C 充放电

贮存寿命  Storage life

2 

 

物理特性

Physical properties

质量 mass

 8.2KG

 

(L*W*H)size

500*480*100mm

 

 

河南品越电子科技有限公司

 

 

张工 15538577277        5    13  

 

img5

 

超级电容模组  V1.00

4. 产品外形图、尺 Product shape and size

img6

 

 

5. 产品端子定 Product Terminal Definition

 

端子号

端子名称

定义

1

+

模组正极

2

PE

外壳接地

3

-

模组负极

6. 测试方 Testing Methods:

6.1 容量测试电路原 Principle of capacity test circuit

 

img7

1 恒流放电方法电路Constant current method circuit

 

 

河南品越电子科技有限公司

 

 

张工 15538577277        6    13  

 

 

超级电容模组  V1.00

img86.2 容量测量方 Capacity measurement method

——恒流/恒压源的直流电压设定为额定电压(URThe DC voltage of the constant current/constant voltage source is set to the rated voltage

——设定恒电流放电装置的恒定电流值 ISet the constant current value I of the constant current discharge device

——将开 S 切换到直流电源,电容器恒流充电到额定电压并恒压 30min 后转换为恒流放电 Switch S to the DC power supply, the capacitor is charged to the rated voltage at constant current and then converted to constant current after 30min of constant voltage

 

img9

2  电容量测试示意 Schematic diagram of capacitance test

测量电容器两端电压 U1  U2 的时 t1  t2 ,如 2 所示,根据下列等式计算电容量值 Measure the time T1 and T2 of the voltage from U1 to U2 at both ends of the capacitor, as shown in FIG. 2. Calculate the capacitance value according to the following equation:

img10

式中 Type in the

CR——容量(Fcapacity

I——放电电 1C(mA))Discharge Current 1C(mA)

U1——测量初始电压 U1=3.8*N(V)Voltage before test:U1=3.8*N(V) U2 ——测量终止电压 U2=2.7*N(V)Voltage after test:U2=2.7*N(V)

t1——放电初始到 U1( s )  电压的时间 Time between initial discharge and voltage reaching U1(s) t2——放电初始到 U2( s )  电压的时间 Time from initial discharge to voltage reaching U2(s)

6.3 交流内 AC ESR

6.3.1测试电路原理Principle of test circuit

 

img11

 

超级电容模组  V1.00

 

img12

3 交流阻抗电 AC impedance circuit

6.3.2测量方法Method of measurement

电容器的交流内 ESRAC  应通过下式计 The  AC  internal  resistance  ESRAC  of  the  capacitor  shall  be calculated as follows:

img13

式中 Type in the

ESRAC——交流内(Ω) Ac internal resistance

U——交流电压有效值(VEffective value of AC voltage I——交流电流有效值(AEffective value of AC current

测量电压的频率应为 1kHzThe voltageshall be measuredata frequency of 1kHz 交流电流应为 1mA  10mAAc current should be 1mAto 10mA

6.4 直流内阻

6.4.1测试方法Method of measurement

——恒流/恒压源的直流电压设定为额定电压( UR )The DC voltage of the constant current/constant voltage source is set to the rated voltage

——设定恒电流放电装置的恒定电流值 I Set the constant current value I of the constant current discharge device

——将开关 S 切换到直流电源,电容器恒流充电到额定电压并恒压 30min 后转换为恒流放电 Switch S to DC power supply, capacitor constant current charge to rated voltage and constant voltage 30min after conversion to constant current current;

——用电压记录仪记录电容器充放电转换端电压瞬 10ms 压降的变化 ΔU3,如 2 所示 A voltage recorder was used to record the change of 10ms voltage drop ΔU3  at the transient voltage of the charging and discharging terminal of the capacitor, as shown in Figure 2

根据下式计算直流内阻 ESRDC Calculate the DC internal resistance according to the following equation

img14

式中 Type in the

ESRDC——直流内(Ω) The dc resistance

 

 

超级电容模组  V1.00

img15ΔU310ms 电压降(V10 ms voltage drop

I ——放电电 1C(mA))Discharge Current 1C(mA)

6.5 漏电 Leakage current

——测量之前待测锂离子电容器应充分开路静置,一般静 12h 以上 Before measurement, the lithium ion capacitor to be measured shall be fully open-circuit and allowed to stand for more than 12h

——恒流/恒压源的直流电压设定为额定电压( UR )Constant current/constant voltage source DC voltage set to rated voltage (UR)

——选择合适的保护电 RS,经过最 30min 充电时间后达 95%充电 The appropriate protection resistance RS is selected to reach 95% charging voltage after the maximum charging time of 30min

——用电压表记录 72h 后保护电阻两端的电压 US ,如图 4 所示 Use a voltmeter to record the voltage (US) at both ends of the protection resistance after 72h, as shown in figure 4

——漏电流 LC 值即为 US/RS 的比值 LC value of leakage current is the ratio of US/RS

img16

4 漏电流测试电路图Leakage current test circuit diagram 有关相应标准规定Relevant relevant standard provisions

——测试参考温度20,在其他温度测量时应有相关修正系The reference temperature of the test is 20.When measuring other temperatures, there should be relevant correction coefficient ——规定充电时间 Set charging time

——高精度的稳压电源 High precision regulated power supply ——高精密的保护电阻 High precision protection resistor

6.6 自放电

——测量之前待测锂离子电容器应充分开路静置,一般静 12h 以上 Before measurement, the lithium ion capacitor to be measured shall be fully open-circuit and allowed to stand for more than 12h

——恒流/恒压源的直流电压设定为额定电压( UR )The DC voltage of the constant current/constant voltage source is set to the rated voltage( UR )

——设定规定的恒电流放电装置的恒定电流值 Set the constant current value of the specified constant current discharge device

——将开关 S 切换到直流电源进行恒流充电,经过最大 30min 充电时间后达到 95%充电电压 Switch S to DC power supply for constant current charging, and 95% charging voltage will be reached after the maximum

 

 

超级电容模组  V1.00

img17charging time of 30min

——在恒流/恒压源达到额定电压后恒压充电 8hCharge  at  constant  voltage  for   8h  after  the  constant current/constant voltage source reaches the rated voltage

——在恒压充电 8h 结束后,将电容器两端从电压源断开,置于标准条件下 24h 后,测量电容器两端的残 留电压 Uc,如图 5 所示 At the end of 8h of constant voltage charging, both ends of the capacitor are disconnected from the voltage source, and the residual voltage Uc at both ends of the capacitor is measured after 24h under standard conditions, as shown in Figure 5

img18

 

5  自放电测试曲线图Self-discharge test curve

 

7.包装、运输、储 Packaging, transportation, storage

7.1  Packaging

锂离子电容模组使用包装箱包装。包装时应注意各部分的放置方向要求 The LIC capacitor module is packed in a packing box. Pay attention to the placement direction of each part when packing

7.2 运输 transportation

适合汽车、火车和轮船的运输  在搬运过程中,应小心轻放,以免将器件震坏。中途转运时不得露天存放,运输过程中 应避免雨、雪或其它液体物质的淋袭,太阳久晒及机械损伤等。在运输时应严格按包装箱上所标示的方向放置,以免将器件  Suitable for transport by car, train and ship; In the process of handling, should be careful to avoid the device will be damaged. Do not store in the open air during transit. During transportation, avoid rain, snow or other liquid substances, long exposure to the sun and mechanical damage. During transportation, place the device in the direction indicated on the packing case to avoid device damage

7.3  storage

系统储存时应放在干燥的仓库中,不得暴晒和雨淋。放置方向应符合包装箱上的标志,产品贮存环境温度-40~  +70。仓库内不允许有各种有害气体、易燃、易爆的物品及有腐蚀性的化学物品,并且应无强烈的机械振动、冲击和强磁

 

 

超级电容模组  V1.00

img19场作 The system should be stored in a dry warehouse, not exposed to the sun and rain. The product shall be

 

placed in accordance with the label on the packing case. The temperature of the storage environment is -40 ° C to +70 ° C. All kinds of harmful gases, inflammable, explosive articles and corrosive chemicals are not allowed in the warehouse, and there should be no strong mechanical vibration, impact and strong magnetic field.

备注:产品在长时间运输过程中及长期不使用储存过程中,应存放在适宜的环境 The product should be stored in a suitable environment during longtime transportation and longtime storage without use.

8.注意事 Notice:

8.1 使用注意事 Precautions for Use

a、在使用锂离子电容模组前请仔细阅读本说明书,书中包含关于超级电容的安全、运输、安装、维护等重要信息违反安 全指南可能导致直接或间接的伤害或损 Please read this manual carefully before using the LIC capacitor module. This manual contains important information about the safety, transportation, installation, and maintenance of supercapacitors. Violation of this manual may result in direct or indirect injury or damage

b、在起动装置之前,先确认负载的安全状况,然后按照使用手册进行操作。随意地上电,有产生触电等事故的危险Before starting the device, confirm the safety condition of the load, and then operate according to the manual.Random electricity, there is a danger of electric shock and other accidents.

c、在装置周围,切勿使用烟火。由于爆炸和损坏,可能会导致人身伤害和火  Do  not  use fireworks  around the installation. Personal injury and fire may result from explosion and damage.

d、切勿将模组当作踏板。否则,会造成模组内部元器件损  Do not use modules as pedals. Otherwise, internal components of the module will be damaged.

e、通电状态, 输出端子之间切勿短路。由于电流回流将产生电弧, 其弧光会导致人员灼伤和视觉损 When power is on, do not short circuit between output terminals. Because the current flow back will produce an arc, its arc light can cause human burns and visual damage.

8.2 安装注意事 Installation Precautions

a、绝对禁止在如下环境中使用或保管。否则会因设备的故障  损伤及老化而导致发生火灾。超出使用手册所记载的周围 环境条件范围的高温、低温、潮湿的场所。从电炉等热源直接受热的场所。产生火花的机械设备的附近。其它类似于上述 的环 It is absolutely prohibited to use or keep in the following environment. Otherwise, fire may occur due to equipment failure, damage and aging. Places with high temperature, low temperature and humidity beyond the range of ambient conditions described in the manual. A place heated directly from a heat source such as an electric furnace. In the vicinity of mechanical devices that generate sparks. Other environments similar to the above.

 

img20

 

超级电容模组  V1.00

b、请按照使用手册,将设备安装在能够承受其重量的场所。如果安装不完善,可能就会因设备跌落而造成设备损害 Install the device in a place that can support its weight according to the user manual. If the installation is not perfect, it may cause equipment damage due to falling equipment.

c、请勿放在可燃物附近。否则有引起火灾的危 Do not place near combustibles. Otherwise there is a risk of fire.

d、谨防杂物进入模组内部。否则有引起设备故障的危  Beware of debris entering the module. Otherwise, the device may fail.

e、请勿使用有损伤、缺部件或有凹坑等的电容设备。否则有引起触电,人身伤害及火灾等事故的危 Do not use the ultracapacitor with damage, missing parts, or pits. Otherwise, there is a risk of electric shock, personal injury and fire.

8.3 搬运和移动时的注意事 Precautions for handling and moving

在搬运和移动过程中,请勿同时触碰正负极。否则有触电危险。安装在能够承受其重量的场所。如果安装不完善,可   能会因设备跌落而造成设备损 Do not touch the positive and negative poles at the sametime during handling and moving. Otherwise there is a risk of electric shock.

8.4 运转操作时的注意事 Points for attention during operation

a、请在标定电压、电流、温度范围内适用本产品,否则会造成设备的损坏Please apply this product within the range of rated voltage, current and temperature, otherwise the equipment will be damaged

b、不允许过充、过放本产品,否则会造成无法修复的损坏It is not allowed to overcharge or over-discharge this product, otherwise it will cause irreparable damage

c、模组不允许欠压,任何闲置情况下,请 6 个月内进行充电,否则会出现不可恢复欠压损坏The module is not allowed to be under voltage. In any idle condition, please charge it within 6 months; Otherwise, irrecoverable undervoltage damage will occur

d、出现设备报警时,请停止使用,并及时联系厂家技术支持In case of equipment alarm, please stop using and contact the manufacturer's technical support in time.

8.5 维护检查时的注意事 Precautions for maintenance checks

除了专业电气施工人员以外,其他人员不可进行维护、检查和更换零部件等作业。请使用绝缘防护工,否则有触电和 被烫伤的危 Personnel other than professional electrical construction personnel are not allowed to carry out maintenance, inspection, and replacement of parts. Use insulated protective tools, otherwise there is a risk of electric shock and burns.

8.6 关于废 About ghost

废弃本产品时,请委托专门的工业废弃物处理机构( *)进行处理。如果不委托专业人员进行处理,那么由于电容器的 爆炸或产生的有害气体就会造成人身伤害。( *)所谓专业的废弃物处理机构是[工业废弃物回收搬运机构][工业废弃物 处理机]。如果对于工业废弃物的回收、搬运以及处理未经许可而擅自进行者  将受到法律制[关于工业品的处理和清 扫的法]When discarding this product, please entrust a special industrial waste disposal organization (*) to deal with it. If not professionally handled, personal injury may result from the explosion of the capacitor or the

 

harmful gas produced. (*) The so-called professional waste disposal organization refers to [Industrial waste Recovery and Handling Organization] and [Industrial Waste Disposal Organization]. If the recycling, handling and disposal of industrial waste are carried out without permission, they will be subject to legal sanctions. [Law on the handling and cleaning of industrial Goods]

8.7 其它方面的注意事 Other considerations

a、严禁擅自对产品进行改造。否则有引起触电、人身伤害、故障、损坏和火灾的危险 It is strictly prohibited to modify the product without authorization. Risk of electric shock, personal injury, failure, damage and fire.

b、由于本产品发生故障而可能引起重大事故、或引发重大损失时  对于这类情况请配置安全装置。否则有引起事故的  If the fault of the product may cause serious accidents or heavy losses, please configure safety devices for such situations. Otherwise there is a risk of an accident.

c、其他  在使用锂离子电容器的过程中出现的其他应用上的问题,请咨询上海永铭电子股份有限公司或参照超级电容 器使用说明的相关技术资料执行Others: If any case or question happen during using L, pls contact Shanghai Yongming Electronic or refer the datasheet we provided.

9.客户需 needs of customers

如果贵司对该文件所描述的应用、操作指南仍未满足需求, 还请事先填写如下表格信息,并与上海永铭电子股份有限公司 联系,敝司继承着有困难找永铭之原则,将为贵司所提出的特殊需求进行设计及制造,以满足贵司之需求。

Please Contact Shanghai Yongming Electronic if you have any other requirement or if you are not satisfied with our data sheet

 

NO.

已有信息

Information mentioned

in the data sheet

特殊信息

Special information you

need

现在标准 Standard

需求标准

Special requirement

 

 

 

 

 

 

 

 

 

 

公司名 Company Name                               签名及联系方 Sign                             

日期 Date                

 

 

 

 

 

 

 

 

 

 

 

 

 

 

河南品越电子科技有限公司

 

 

张工 15538577277  13   13